beautypg.com

E. electrical connection, Warning, E. electrical connection warning – Hoshizaki KML-700MWH-M User Manual

Page 9: Fig. 3, Electrical connection

background image

9

E. Electrical Connection

WARNING

1. Electrical connection must be hard-wired and must meet international,

national, state, and local electrical code requirements. Failure to meet these
code requirements could result in death, electric shock, serious injury, fire, or
severe damage to equipment.

2. This unit requires an independent power supply. See the nameplate for

proper voltage and breaker/fuse size. Failure to use a proper breaker or fuse
can result in a tripped breaker, blown fuse, or damage to existing wiring. This
could lead to heat generation or fire.

3.

THIS UNIT MUST BE GROUNDED. Failure to properly ground this unit
could result in death or serious injury.

4. Electrical connection must be made in accordance with the instructions on

the "WARNING" tag, provided with the pig tail leads in the junction box. See
Fig. 3.

• Usually an electrical permit and services of a licensed electrician are required.
• The maximum allowable voltage variation is ±10 percent of the nameplate rating.
• The transformer's voltage tap switch must be positioned to match incoming voltage at

startup.

• The opening for the power supply connection is 7/8" DIA to fit a 1/2" trade size conduit.

Fig. 3

KML-700MWH-M

 WARNING

ELECTRICAL CONNECTION

THIS UNIT MUST BE GROUNDED
Failure to properly ground or wire
this unit could result in death,
serious injury, or severe damage to
the icemaker.
The transformer’s voltage tap switch
must be positioned to match incoming
voltage at startup.
See diagram below.

4A4741-010

208-230/60/1

BROWN

JUNCTION BOX

20

8-2

30

V

BLACK

L1

L2