Heat & Glo Fireplace XLR-N-CE User Manual
Page 48
Heat & Glo • XLR-N-CE, XLR-PB-CE • 2198-900 Rev. L • 3/13
48
Non-Combustible Finish Material 0-10 cm Thick
Bottom Joint
1,9 cm
1,9 cm
4,6 cm
Figure 13.9 Noncombustible Surface Finishing Material 0 - 10
cm Thick-Inside Fit Method (Tonic Decorative Front
Only)
Figure 13.8 Inside Fit Method (Tonic Decorative Front Only)
Non-Combustible Finish Materials
0 cm to 10,16 cm Thick Inside Fit Method
The Tonic decorative front is approved for inside fit appli-
cations. Non-combustible finishing materials up to 10,16
cm thick can be installed around the front (left, right, top,
and bottom).
For the Tonic decorative front inside fit applications, the
decorative front must be installed tight to the finishing
flanges and must not overlap any finish material.
Ensure that no non-combustible finish materials are in-
stalled within 1,9 cm of the fireplace opening. The 1,9
cm spacing is required to provide clearance for removing
and installing the Tonic decorative front. See Figure 13.9.
FACTORY-INSTALLED
NON-COMBUSTIBLE
BOARD
DRYWALL OR
EQUIVALENT
(1,3 cm)
52 cm APPLIANCE
OPENING (HEIGHT)
1,9 cm
4,6 cm
0-10 cm
0-10 cm