Operating the Nailer

1. Attach the Nailer to the air supply at the

Air Inlet (38). Start your compressor and check

the pressure making sure it is set at the recommended 55-95 PSI and not to go over the

maximum 95 PSI.

2. To fire, place the nose of the Nailer on the workpiece. The Nailer should not fire if the

nose is not depressed. Once depressed, gently and briefly squeeze the

Trigger (29)

once.

Do not fire repeatedly. Nails could bounce off of one another, damaging the

work piece or causing PERSONAL INJURY.

Operation (continued)

Loading Brad Nails

ALWAYS WEAR ANSI APPROVED IMPACT SAFETY GOGGLES WHEN

RELOADING OR DOING ANY OTHER MAINTENANCE ON THIS TOOL. Other

people in the work area must also wear ANSI approved impact safety goggles.

Warning! Make sure the Nailer is not attached to the air hose whenever loading the

tool.
1. Press the

Retaining Spring (58) up and slide the Magazine (60) back.

2. Holding the nailer with the nose pointing slightly down, insert the brad nails into the

Magazine (60), letting the pointed end ride on the rail of the Magazine (60).

3. After the Nails reach the nose of the tool, close the

Magazine (60) making sure the

Retaining Spring (58) clicks shut. See Figure 1.

Air Inlet (38)

Magazine (60)

Safety

Trigger (29)

Retaining Spring (58)

FIGURE 1