beautypg.com

Harbor Freight Tools CENTRAL PNEUMATIC 46309 User Manual

Page 5

background image

SKU 46309

Page 5

For technical questions, please call 1-800-444-3353.

Testing the Full Sequential Safety Trip Mechanism

Warning: Even though the nailer should be empty during this procedure, ALWAYS point

the nailer at a piece of scrap wood when testing.

1. Make sure the tool is disconnected from the power supply.
2. Completely empty the magazine of nails.
3. The Nailer should not fire if the nose is not depressed against the workpiece.
4.

Check that the

Trigger (29) and the Safety (56) move freely, without sticking - see Figure

1, next page.

5. Connect the air supply to the tool at the

Air Inlet (38) set at the recommended 55-95

PSI, and not to go over the maximum 95 PSI.

6. Test the tool by depressing the

Safety (56) against the workpiece without pulling the

Trigger (29). The tool must not cycle (fire). If it cycles (fires), stop immediately and

take the tool to an authorized service technician.

7. Hold the tool away or off of the workpiece. The

Safety (56) of the tool should return to

its original position. Squeeze the

Trigger (29). The tool should not cycle (fire). If it

cycles (fires), stop immediately and take the tool to an authorized service technician.

8. Depress the

Safety (56) against the workpiece and squeeze the Trigger (29). The

tool must cycle (fire) once only. Release the trigger and squeeze it again. The tool

must not cycle (fire). With the Trigger held, carefully lift the nailer and press it against

the workpiece again.

The tool must not cycle (fire). If it fails to act in the manner

described in bold, have it repaired by a qualified service technician.

Unpacking

When unpacking, check to make sure the parts listed on page 8 are

included. If any parts are missing or broken, please call Harbor Freight Tools at

the number on the cover of this manual as soon as possible.

NOTE: Although a spare Drive Pin (46), Step Pin (45), Piston Head (44), O-ring (43), and

assorted O-rings are included, these parts are for installation by a qualified technician only.

Operation

For best service, you should incorporate an oiler, regulator, and inline filter, as shown in

the diagram below. Hoses, couplers, oilers, regulators, and filters are all available at Harbor

Freight Tools.

Note: To connect this tool, we recommend a quick coupler/adapter (not included). Coupler/

adapters are available at Harbor Freight Tools. If an automatic oiler is not used, put

3-5 drops of pneumatic tool oil in the

Air Inlet (38) before each use.

Nailer