Warning, Framing and clearances – Hearth and Home Technologies Dakota 42-CE User Manual
Page 5

Heat & Glo Lifestyle Collection • Dakota 42-CE • 4036-915 Rev I • 11/07
5
B
A
G
E
Note: If this surface is
inside the building’s
warm air envelope...
...then this surface
must be an exterior
wall system.
C
D
F
F
C
D
G
F
E
1.47 M
2.08 M
Note:
• Illustrations
refl ect typical installations and are FOR
DESIGN PURPOSES ONLY.
• Illustrations/diagrams are not drawn to scale.
• Actual installation may vary due to individual design
preference.
Fire Risk
Provide adequate clearance:
• Around air openings.
• To
combustibles.
• For service access.
Locate fi replace away from traffi c areas.
WARNING
A. Select Fireplace Location
When selecting a location for your fi replace it is important to
consider the required clearances to walls (See Figure 3.1).
Note: For actual f ireplace
dimensions refer to Section 13.
Figure 3.1 Fireplace Locations
3
3
Framing and Clearances
Fire Risk
Odor Risk
• Install
fi replace on hard metal or wood
surfaces extending full width and depth
of fi replace.
• Do NOT install fireplace directly on
carpeting, vinyl, tile or any combustible
material other than wood.
WARNING
Fire Risk
• Locate and install fi replace to all clearance
specifi cations in manual.
WARNING
A
B
C
D
E
F
G
cm
62.9
61.3
121.9
124.5
1.6
1.3
3.8