A. valve access and service – Hearth and Home Technologies Dakota 42-CE User Manual
Page 21
Heat & Glo Lifestyle Collection • Dakota 42-CE • 4036-915 Rev I • 11/07
21
A. Valve Access and Service
Figure 11.1 Lift Out Doors
Figure 11.3 Loosen Refractory Retaining Strip
Figure 11.4 Remove Valve Access Panel
Figure 11.5 Remove Exterior Valve Access Panel
Figure 11.6 Connect Manometer
• The gas valve can be accessed behind the cement
refractory panel on the right side of the fi replace.
• Lift doors out and set aside. There is a washer under each
door. Be careful not to lose the washers.
• Use a phillips screwdriver to remove the exterior valve
access panel (remove four screws).
• Loosen lower pressure tap screw before attaching
manometer. Start up the fi replace to verify the pressure
and adjust as necessary. Reverse these steps to
reassemble before log positioning.
Note: Pressure tap screws must be re-tightened.
• Remove logs if access is necessary after installation is
complete. See Section 9.C. Remove logs in reverse order
of set up.
• Remove grate if access is necessary after installation is
complete. (Refer to Section 9.B.)
• Remove two screws on side of pilot shield and remove
shield.
• Remove the inside valve access panel by lifting it up and
out.
Figure 11.2 Remove Pilot Shield
• Use a phillips screwdriver to remove the two screws
securing the refractory retaining strip. Remove the
refractory side panel and set aside.
WASHER