A. Valve Access and Service

Figure 11.1 Lift Out Doors

Figure 11.3 Loosen Refractory Retaining Strip

Figure 11.4 Remove Valve Access Panel

Figure 11.5 Remove Exterior Valve Access Panel

Figure 11.6 Connect Manometer

• The gas valve can be accessed behind the cement

refractory panel on the right side of the fi replace.

• Lift doors out and set aside. There is a washer under each

door. Be careful not to lose the washers.

• Use a phillips screwdriver to remove the exterior valve

access panel (remove four screws).

• Loosen lower pressure tap screw before attaching

manometer. Start up the fi replace to verify the pressure
and adjust as necessary. Reverse these steps to
reassemble before log positioning.

Note: Pressure tap screws must be re-tightened.

• Remove logs if access is necessary after installation is

complete. See Section 9.C. Remove logs in reverse order
of set up.

• Remove grate if access is necessary after installation is

complete. (Refer to Section 9.B.)

• Remove two screws on side of pilot shield and remove

shield.

• Remove the inside valve access panel by lifting it up and

out.

Figure 11.2 Remove Pilot Shield

• Use a phillips screwdriver to remove the two screws

securing the refractory retaining strip. Remove the
refractory side panel and set aside.

WASHER