13

!

Figure 9. Gas Supply Line

• At the gas line access hole, use insulation to re-pack

the space around the gas pipe.

• Insert insulation from the outside of the fireplace and

pack the insulation tightly to totally seal between the

pipe and the outer casing.

Step 7. The Gas Supply Line

NOTE: Have the gas supply line installed in accordance

with local building codes by a qualified installer

approved and/or licensed as required by the locality.

!

USE A WRENCH ON

SHUT-OFF VALVE WHEN

TIGHTENING GAS LINE

GAS VALVE

FLEX

CONNECTOR

MANUAL

SHUT-OFF VALVE

WARNING: THIS UNIT IS NOT FOR USE WITH

SOLID FUEL.

!

!

Step 6. The Gas Controls System

WARNING: DO NOT USE AN OPEN FLAME

TO CHECK FOR GAS LEAKS.

GAS

ACCESS

Two types of gas control systems are used with these models:

Standing Pilot Ignition and Direct Spark Ignition (DSI).

Standing Pilot Ignition System
This system includes millivolt control valve, standing pilot,

thermopile/thermocouple flame sensor, and piezo ignitor.

WARNING: 110-120 VAC MUST NEVER BE

CONNECTED TO A CONTROL VALVE IN A

MILLIVOLT SYSTEM.

Direct Spark Ignition (DSI) System
This system includes a 24V control valve, electronic module,

transformer, and spark ignitor/flame sensor.

WARNING: 110-120 VAC MUST BE WIRED TO

THE FIREPLACE JUNCTION BOX IN A DSI

SYSTEM.

NOTE: Before the first firing of the fireplace, the gas

supply line should be purged of any trapped air.
NOTE: Consult local building codes to properly size

the gas supply line leading to the 1/2 inch (13mm) hook-

up at the unit.

This gas fireplace is designed to accept a 1/2 inch (13mm)

gas supply line.
To install the gas supply line:
• A listed (and State of Massachusetts approved) 1/2 inch

(13mm) tee-handle manual shut-off valve and a listed flex-

ible gas connector are connected to the 1/2 inch (13mm)

inlet of the control valve. NOTE: If substituting for these

components, please consult local codes for compliance.

• Locate the gas line access hole in the outer casing of

the fireplace.

• The gap between the supply piping and gas access hole

can be plugged with non-combustible insulation to pre-

vent cold air infiltration.

• Insert the gas supply line through the gas line hole, and

connect it to the shut-off valve.

• When attaching the pipe, support the control so that the

lines are not bent or torn.

• After the gas line installation is complete, use a soap

solution to carefully check all gas connections for leaks.

Figure 8. Gas Supply Line

3/8” (10mm)

STANDING PILOT

DSI IGNITION

3/16” (5mm)

CERAMIC

INSULATOR

IGNITOR

1/2” (13mm)