beautypg.com

Creating the auto log on user account, Configuring the tec session to launch at reboot – HP AB300A User Manual

Page 11

background image

AB300A Console User Guide

11

Creating the Auto Log On User Account

1. Create a login user by selecting Start > Settings > Control Panel.
2. Double click the Security icon and select the Users tab.

3. Create a new user, such as vt-100 user, by clicking Add and entering the new user

name. Click OK.

NOTE: Do not assign a password for the new user at this time.

4. Select the System tab on the Security screen. Select the new user name you just created

as the account by clicking on the Account drop down menu and selecting the new user
name. Click OK.

5. Close the Control Panel by clicking on the X in the upper right hand corner of the

screen.

Configuring the TEC Session to Launch at Reboot

1. Create a TEC session using one of the above mentioned methods

.

Assign a name to the

connection, such as " connection1 (TEC).”

2. Select Start > Programs > Connection Administrator
3. Click the Advance

button.

4. Select the “Global UI” tab.
5. Select the “Auto Start Connection Administrator when logging into Windows” tab.

NOTE: When creating a new profile, a default name of “New Profile” is created. Highlighting the newly
created profile name, then single-clicking within the name text will allow the name to be modified.

6. Select the “Assign Connection” tab.
7. Select the proper User in the drop down.
8. On the available connection window on the left, double click on the TEC session name

created earlier.

9. On the right hand side of the screen, single click the “No” under auto.

10. Under Connection Options, select the Automatically Connect

option. Under Windows

Start Mode, select Kiosk. Click OK.

11. Reboot. The TEC session will launch at reboot.

NOTE: When using Kiosk mode within the Windows Start Mode, the only application available for
the user will be the configured terminal emulator after a thin client reboot. When using the Auto mode
within the Windows Start Mode, the emulator will automatically launch after a thin client reboot, but
full system access will be available to the user.

If Kiosk mode is selected, and the administrator wishes to access administrative features of the thin
client, then the thin client must be rebooted. The reboot must be performed by recycling power on
the thin client.
During the reboot, a small window will appear with a 5 second countdown. During this
countdown, simultaneously pressing the Altand “F4 buttons will interrupt the boot, and allow the
administrator to log in. If the administrator password has been set, the password will also be required.