Fig. 1. Typical location of thermostat.

1. Position and level the wallplate (for appearance

only). The thermostat functions correctly even
when not level.

2. Use a pencil to mark the mounting holes.

See Fig. 2.

3. Remove the wallplate from the wall and drill two

3/16 inch (76 mm) holes in the wall (if drywall) as
marked. For firmer material such as plaster, drill
two 7/32 inch (5.56 mm) holes. Gently tap anchors
(provided) into drilled holes until flush with wall.

4. Position the wallplate over the holes, pulling wires

through the wiring opening.

5. Loosely insert the mounting screws into the holes.
6. Tighten mounting screws.

Fig. 2. Mounting the wallplate.

WIRING

All wiring must comply with local electrical codes and
ordinances. Refer to Fig. 3 and 6 for typical hookup. A
letter code is located near each terminal for identification.

CAUTION

Electrical Hazard.
Can cause electric shock or equipment
damage.
Disconnect power before wiring.

1. Loosen the terminal screws on the wallplate and

connect the system wires. See Fig. 7.

IMPORTANT

Use 18 gauge, color-coded thermostat cable for
proper wiring.

2. Securely tighten each terminal screw.
3. Push excess wire back into the hole.
4. Plug the hole with nonflammable insulation to

prevent drafts from affecting the thermostat.

Fig. 3. Typical hookup in heat application.

5 FEET

[1.5 METERS]

YES

NO

NO

NO

M10106

WIRES
THROUGH WALL

WALL

MOUNTING
HOLES

M15044

MOUNTING
SCREWS

WALL
ANCHORS (2)

L1
(HOT)

L2

M10409

FAN
RELAY

G

THERMOSTAT

HEAT
RELAY

R

W

TRANSFORMER

POWER SUPPLY. PROVIDE DISCONNECT MEANS AND
OVERLOAD PROTECTION AS REQUIRED.