Troubleshooting

Problem

Possible Causes

Likely Solutions

Tool will not start.

1. Cord not connected.
2. No power at outlet.

3. Tool’s thermal reset breaker

tripped (if equipped).

4. Internal damage or wear.

(Carbon brushes or

switch, for example.)

1. Check that cord is plugged in.
2. Check power at outlet. If outlet is unpowered,

turn off tool and check circuit breaker.

If breaker is tripped, make sure circuit is right

capacity for tool and circuit has no other loads.

3. Turn off tool and allow to cool.

Press reset button on tool.

4. Have technician service tool.

Tool operates slowly. 1. Forcing tool to work too fast.

2. Extension cord too long or cord

diameter too small.

1. Allow tool to work at its own rate.
2. Eliminate use of extension cord. If an extension

cord is needed, use one with the proper diameter

for its length and load. See Extension Cords

in Grounding section on page 6.

Performance

decreases over time.

1. Carbon brushes worn

or damaged.

2. Bit dull or damaged.

1. Have qualified technician replace brushes.

2. Keep bits sharp. Replace as needed.

Excessive noise

or rattling.

Internal damage or wear. (Carbon

brushes or bearings, for example.)

Have technician service tool.

Drill bit slips

in chuck.

1. Jaws are loose.
2. Bit is jammed in workpiece.

1. Tighten chuck .
2. Tighten chuck, then operate tool in

reverse to back bit out of workpiece.

Overheating.

1. Forcing tool to work too fast.
2. Bit dull or damaged.
3. Blocked motor housing vents.

4. Motor being strained by long or

small diameter extension cord.

1. Allow tool to work at its own rate.
2. Keep bits sharp. Replace as needed.
3. Wear ANSI-approved safety goggles and

NIOSH-approved dust mask/respirator while

blowing dust out of motor using compressed air.

4. Eliminate use of extension cord. If an extension

cord is needed, use one with the proper diameter

for its length and load. See Extension Cords

in Grounding section on page 6.