Model HCS-2,HCW-3/HCW-5/HCW-8
PROBLEM
CAUSE
CORRECTION
WATER SYSTEM
A. Water will
•
Faulty float switch
•
Check float switch per
not fill
Float Switch section
•
Faulty water control switch
•
Check water control switch
per Water Control Switch
section
•
Faulty water valve
•
Check water valve per
Water Valve section
•
Water supply has been shut
•
Check the water supply
off or disconnected
LIGHTING
A. Lights will
•
Defective fuse
•
Check per Fuse section
not turn on
•
Faulty light switch
•
Check light switch per
Light Switch section
•
No neutral supplied in field
•
Check field wiring to be sure
wiring
a true neutral has been
connected
•
Loose or defective wiring
•
Check wiring and repair and
replace if necessary
B. Not all lights on
•
Faulty light bulbs
•
Replace with recommended
bulb per Light Bulb section
•
Faulty light switch
•
Check light switch per
Light Switch section
103