Henny Penny HCS-2 User Manual
Page 6

Model HCS-2,HCW-3/HCW-5/HCW-8
PROBLEM
CAUSE
CORRECTION
THERMOMETER
A. Reading does
•
Thermometer bulb is not in
•
Insert bulb in block
not match
holding block
actual
temperature
•
Faulty thermometer
•
Replace per Thermometer
section
OPERATIONS
A. Product not
•
Doors are not kept closed
•
Keep doors closed when
holding
possible
temperature
•
Product held too long
•
Only hold product for
recommended times
•
Water temperature too low
•
Check water heating system
per Water Pan Heater section
•
Radiant heat too low
•
Turn to higher setting
•
Radiant heat not working
•
Check radiant heat system per
Radiant Heater section
•
Light bulbs out
•
Replace as required, per
Light Bulb section
B. Doors are
•
Doors left open too much
•
Keep doors closed when
fogging
allowing doors to cool and
possible
cause condensation
•
Radiant heat not high enough
•
Turn to higher setting
•
Radiant heat not working
•
Check radiant heater per
Radiant Heater section
•
Water temperature too high
•
See recommended settings
and temperatures
1-2
103
1-3. TROUBLESHOOTING (Continued)