beautypg.com

Framing and clearances, Warning – Hearth and Home Technologies HUDBAY-INS User Manual

Page 6

background image

Quadra-Fire • Hudson Bay Insert • 7008-115 Rev. H • 10/08

6

Figure 3.1

Model

A

B

C

D

Hudson Bay Insert

Inches 14

11

12

7

Millimeters

356

279

305

178

B. Clearances to Combustibles

3

3

Framing and Clearances

Note:
Illustrations reflect typical installations and are FOR

DESIGN PURPOSES ONLY.

Illustrations/diagrams are not drawn to scale.

Actual installation may vary due to individual design

preference.

Fire Risk

Provide adequate clearance:

• Around air openings

• To combustibles

• For service access

Locate appliance away from traffi c areas.

A. Selecting Appliance Location

When selecting a location for your appliance it is important to
consider the required clearances to walls (see fi gure 3.1).

NOTE: For actual appliance dimensions refer to Sec-
tion 12.

WARNING

Underneath bottom of appliance to combustibles: 3/8 in. (10 mm)

16 in. (406 mm) front floor protection required 0 in. to 2-1/2 in. (64 mm) below bottom of appliance. (1/2 in. of "k" = .84)

No floor protection needed if 2-1/2 in. (64 mm) or greater from bottom of appliance.

To 8 in. (203 mm ) Deep mantel:
14 in. (356 mm) From top of insert

A

B

D

C

SIDE WALL

HEARTH

1-1/2 in. (38 mm)

16 in. (406 mm)