Framing and clearances, Warning – Hearth and Home Technologies HUDBAY-INS User Manual
Page 6
Quadra-Fire • Hudson Bay Insert • 7008-115 Rev. H • 10/08
6
Figure 3.1
Model
A
B
C
D
Hudson Bay Insert
Inches 14
11
12
7
Millimeters
356
279
305
178
B. Clearances to Combustibles
3
3
Framing and Clearances
Note:
• Illustrations reflect typical installations and are FOR
DESIGN PURPOSES ONLY.
• Illustrations/diagrams are not drawn to scale.
• Actual installation may vary due to individual design
preference.
Fire Risk
Provide adequate clearance:
• Around air openings
• To combustibles
• For service access
Locate appliance away from traffi c areas.
A. Selecting Appliance Location
When selecting a location for your appliance it is important to
consider the required clearances to walls (see fi gure 3.1).
NOTE: For actual appliance dimensions refer to Sec-
tion 12.
WARNING
Underneath bottom of appliance to combustibles: 3/8 in. (10 mm)
16 in. (406 mm) front floor protection required 0 in. to 2-1/2 in. (64 mm) below bottom of appliance. (1/2 in. of "k" = .84)
No floor protection needed if 2-1/2 in. (64 mm) or greater from bottom of appliance.
To 8 in. (203 mm ) Deep mantel:
14 in. (356 mm) From top of insert
A
B
D
C
SIDE WALL
HEARTH
1-1/2 in. (38 mm)
16 in. (406 mm)