beautypg.com

Electrical information, Warning – Hearth and Home Technologies HUDBAY-INS User Manual

Page 14

background image

Quadra-Fire • Hudson Bay Insert • 7008-115 Rev. H • 10/08

14

C. Standing Pilot Ignition System Wiring

This appliance DOES NOT require 110 VAC supply for
operation. A wiring diagram is shown in Figure 7.2 on the
next page.

This appliance is equipped with a millivolt control valve.

Do not connect this appliance to a thermostat serving
any other appliance.

Bedroom installation in Canada requires this appliance
to be connected to a thermostat.

6. Keep wire lengths as short as possible by removing

any excess wire length.

7. Low voltage and 110 VAC voltage cannot be shared

within the same wall box.

8. Ensure the thermostat is mounted level for accurate

readings.

9. The thermostat should be mounted on an inside wall

and not in direct line with the appliance convection air.

10. If the thermostat is located too close to the appli-

ance, you may need to set the temperature setting
slightly higher to maintain the desired temperature
in your home.

Wire Size

Max. Length

16 gauge

65 feet

18 gauge

40 feet

20 gauge

25 feet

22 gauge

18 feet

A. Recommendation for Wire

See Figure 7.1 for recommended maximum lead length
(two wire) when using wall thermostat/switch.

7

7

Electrical Information

NOTE: This appliance must be electrically wired and grounded
in accordance with local codes or, in the absence of local
codes, with National Electric Code ANSI/NFPA 70-latest
edition
or the Canadian Electric Code, CSA C221.1.

B. Connecting to the Appliance

1. This appliance may be used with a wall switch, wall

mounted thermostat and / or a remote control

2. If using thermostat, use one compatible with a millivolt

gas valve system.

3. Follow parameters for locating thermostat (see individ-

ual thermostat instructions) to ensure proper operation
of appliance.

4. Use low resistance thermostat wire for wiring from

ignition system to the wall switch and thermostat.

5. Use the following chart for wire sizing.

WARNING

Shock hazard.

• This appliance is equipped with a three

This appliance is equipped with a three
pronged (grounding) plug for your protection

pronged (grounding) plug for your protection
against shock hazard and should be plugged

against shock hazard and should be plugged
directly into a prop

directly into a properly grounded three prong
receptacle. Do not cut or remove the ground-
ing prong from this plug.

Figure 7.1

• A 110-120 VAC circuit for this product must be protected

with ground-fault circuit-interrupter protection, in
compliance with the applicable electrical codes, when
it is installed in locations such as in bathrooms or near
sinks.