beautypg.com

Installation – Hotpoint EG1000EX User Manual

Page 28

background image

TECHNICAL DATA

DIMENSIONS
Height

900 - 915mm

Width

1000mm

Depth

600mm (excluding door handles)

GENERAL
Gas connection

Rp

1

/

2

(

1

/

2

” BSP female)

Pressure test point

Hotplate burner injector

Gas rate adjustment

None

Aeration adjustment

None

Electrical connection

230/240V a.c. 50Hz.

Total electrical heat input

7.38 kW (EG1000GX) 9.18kW (EG1000EX)

HEAT

INPUT

HEAT

INPUT

BURNER

INJECTOR

HEAT

INPUT

HEAT

INPUT

INJECTOR

Cat II

2H3+

G20 at 20 mbar

Cat II

2H3+

G30 at 28 - 30 mbar
G31 at 37 mbar

240V a.c.

2.66 kW

GRILL

2.50 kW

LEFT OVEN

2.00 kW

RIGHT OVEN

0.22 kW

WARMING
COMPARTMENT

1.0 kW

1.0 kW

HOTPLATE
Front Left

72

3.0 kW

HOTPLATE
Rear Left

128

HOTPLATE
Centre Front Left
(EG1000GX)

2.8 kW

HOTPLATE
Centre Front Right
(EG1000GX)

50

82

75g/hr

210g/hr

1.65 kW

88

1.5 kW

60

110g/hr

1.65 kW

88

1.5 kW

60

110g/hr

2.0 kW

1.8 kW

HOTPLATE
Centre Rear Right

HOTPLATE
Centre Rear Left

102

3.5 kW

HOTPLATE Right

130

3.2 kW

65

90

130g/hr

2.0 kW

1.8 kW

102

65

130g/hr

1.0 kW +

0.8kW

HOTPLATE
Centre Front
(EG1000EX)

235g/hr

28

Installation