beautypg.com

Honeywell B/Q682 User Manual

Page 15

background image

15

69-0563—2

Troubleshooting (continued)

(continued)

2

Problem

Check

Action

No heat (continued).

— other problem.

Contact a qualified service technician for
assistance.

Energy savings
temperature program
12 hours off.

— program dial for proper day or

night phase.

Turn timer ahead 12 hours. Move setting knob
clockwise only.

Rooms do not warm
up at programmed
time.

— timer program for heating

system. May need more time to
warm up rooms.

Move red pin one-half hour earlier on the
program dial.

Temperature change
occurs at the wrong
time.

— programs pins for correct time

locations.

Relocate pins to desired settings.

Room temperatures
are not correct.

— positions of thermostat setpoint

levers.

Reset to desired temperatures.

— position of subbase system

switch (heating-cooling model).

Move to desired operating position.