14
U8AA5540012
and turn the volume while watching the Display Window on the Control Panel.
2. Do not change the amperage and voltage extremely from the initial set values. The
unit may shut down by the error code E42 or E43.
ADJUSTMENT PROCEDURE
Adjust the above set items while electrolyzed water is being dispensed, the Add Salt Water
Lamp is on, or the Service Call Lamp is on.
A1: Cell Lifecycle
1) Run the electrolyzer to dispense electrolyzed water or to turn on the Add Salt Water Lamp
or the Service Call Lamp.
2) Open the Door.
3) The Display Window on the Control Panel shows the present cell lifecycle, amperage (A)
or voltage (V), or an error code. Keep on pushing the Set Button.
4) Check that the Display Window reads “Nor.”, which means the unit is in the normal mode.
5) Keep on pushing the Set Button, and press the Display Button one time.
6) Check that the Display Window reads “AdJ.”, which means the unit is in the adjust mode.
Lighting
Lighting
Lighting
Flashing