D. kni 415/416 indicator, D. kni 415/416 indicator -7 – Honeywell KA 54 User Manual
Page 19
N
KRA 405B RADAR ALTIMETER INSTALLATION MANUAL
Page 1-7
006-10536-0010 Rev. 10
Oct/2005
D.
KNI 415/416 INDICATOR
TSO COMPLIANCE:
C87/ETSO-2C87 DO-138
Env. Cat GAPAAAXXXXXX
PHYSICAL DIMENSIONS:
See
FIGURE 2-5 KNI 415/416 INSTALLATION DRAWING
Length:
Width:
Height:
WEIGHT:
FIGURE 2-5 KNI 415/416 INSTALLATION DRAWING
ALTITUDE:
55,000 feet (16,764 m)
OPERATIONAL TEMPERATURE RANGE:
-20° C to +70° C
POWER REQUIREMENTS:
Primary Power:
27.5 Vdc ± 20% @ 850 mA
Panel Lamp Power: (28 volt units)
28 Vdc ± 10% or 26 Vac ± 10% @ 120 mA
Panel Lamp Power: (5 volt units)
+5 Vdc ± 10% or 5 Vac ± 10% @ 575 mA
ALTITUDE RANGE DISPLAYED:
-20 to 2,000 feet (-6.1 to 609.60 m)
ALTITUDE ACCURACY:
0 to 500 ft:
± 4 feet (1.22 m) or ± 4% (whichever is great-
er)
500 to 2,000 ft:
± 5%
DECISION HEIGHT:
Altitude Range:
(pilot adjustable)
0 to 2,000 feet (0 to 609.60 m)
Accuracy:
± 5 feet (1.27 m) or 5%, whichever is greater
EXTERNAL DECISION HEIGHT OUTPUT:
Isolated pair of relay contacts for switching
external circuit. 110 mA at 28 Vdc, 3 watts
maximum continuous contact load.
VISUAL WARNING SYSTEM:
Pilot Display Warning Flag:
Normal Operation:
Flag hidden from view
Flag Condition:
Power failure or altitude error
Indicator Needle:
Over Altitude:
Needle hidden from view