beautypg.com

Hitachi DH24PB2 User Manual

Page 16

background image

16

English

(1) Mount the core bit to the core bit shank.

(Fig. 15)
Lubricate the thread of the core bit
shank to facilitate disassembly.

(2) Mount the core bit shank to the rotary

hammer. (Fig. 16)

(3) Insert the center pin into the guide plate

until it stops.

(4) Engage the guide plate with the core

bit, and turn the guide plate to left or
right so that it does not fall even if it
faces downward. (Fig. 17)

2. How to bore (Fig. 18)

(1) Connect the plug to the power source.
(2) A spring is installed in the center pin.

Push it lightly to the wall or the floor
straight. Connect all over the surface
of the core bit tip and start operating.

(3) When boring about 3/16" (5 mm) in

depth the position of the hole will
establish. Bore after that removing the
center pin and the guide plate from core
bit.

(4) Application of excessive force will not

only expedite the work, but will
deteriorate the tip edge of the drill bit,
resulting in reduced service life of the
rotary hammer.

CAUTION:

When removing the center pin and the

guide plate, turn OFF the switch and
disconnect the plug form the
receptacle.

3. Dismounting. (Fig. 19)

Remove the core bit shank from the
rotary hammer and strike the head of
the core bit shank strongly two or three
times with the hammer holding the
core bit, then the thread becomes loose
and the core bit can be removed.

Fig. 16

Fig. 18

Fig. 17

Core Bit

Core Bit Tip

Guide Plate

Center Pin

Fig. 19

Core Bit shank

Fig. 15

Core Bit

Thread

Core Bit Shank