System Unit

System Unit

System Unit

System Unit

Dimensions

Dimensions

Dimensions

Dimensions
(HxWxD)
(with feet)

14.5 x 6.9 x 16.8 in (36.7x 17.5 x 42.6 cm)

Weight

Weight

Weight

Weight (approximate)

Maximum
(all hard drives, power
supplies, and processors
installed)

31.35 lb (14.22 kg)

Minimum
(one hard drive, power
supply, and processor
installed)

25.75 lb (11.68 kg)

Input Requirements

Input Requirements

Input Requirements

Input Requirements
(per power supply)

Rated Line Voltage

90 –- 132 VAC,
180 – 264 VAC

Rated Input Current

6 A (at 110 VAC),
3 A (at 200 VAC)

Rated Input Frequency

47 to 63 Hz

Rated Input Power

365 W (at 100 VAC),
365 W (at 200 VAC)

BTU Rating

BTU Rating

BTU Rating

BTU Rating

Maximum

1885 BTU/hr (at 100 VAC),
U/hr (at 200 VAC)

Power Specifications

Power Specifications

Power Specifications

Power Specifications

To review typical system power ratings use the Power Calculator which is
available via the online tool located at URL:

http://h30099.www3.hp.com/configurator/calc/Power%20
Calculator%20Catalog.xls

Power Supply Output

Power Supply Output

Power Supply Output

Power Supply Output
(per power supply)

Rated Steady-State Power 365 W (at 100 VAC),

365 W (at 200 VAC)

Maximum Peak Power

385 W (at 100 VAC),
385 W (at 200 VAC

System Inlet Temperature

System Inlet Temperature

System Inlet Temperature

System Inlet Temperature Operating

10° to 35°C (50° to 95°F) at sea level with an
altitude derating of 1.0°C per every 305 m
(1.8°F per every 1000 ft) above sea level to a
maximum of 3050 m (10,000 ft), no direct
sustained sunlight. Maximum rate of change is
10°C/hr (18°F/hr). The upper limit may be
limited by the type and number of options
installed.
System performance may be reduced if operating
with a fan fault or above 30°C (86°F).

Non-operating

10 to 90% relative humidity (Rh), 28°C
5 to 95% relative humidity (Rh), 38.7°C

Altitude

Altitude

Altitude

Altitude

Operating

3050 m (10,000 ft). This value may be limited by
the type and number of options installed.
Maximum allowable altitude change rate is 457
m/min (1500 ft/min).

Non-operating

9144 m (30,000 ft). Maximum allowable
altitude change rate is 457 m/min (1500 ft/min).