beautypg.com

Technical specifications, Quickspecs – HP Compaq Business PC dc5850 User Manual

Page 16

background image

Unit Environment and Operating
Conditions

Microtower

Small Form Factor

General Unit Operating Guidelines

Keep the computer away from excessive moisture, direct moisture and the extremes of heat and cold, to ensure that
unit is operated within the specified operating range.
Leave a 10.2 cm (4 in) clearance on all vented sides of the computer to permit the required airflow.
Never restrict airflow into the computer by blocking any vents or air intakes.
Do not stack computers on top of each other or place computers so near each other that they are subject to each
other's re-circulated or preheated air.
Occasionally clean the air vents on the front, back, and any other vented side of the computer. Lint, dust and other
foreign matter can block the vents and limit the airflow.
If the computer is to be operated within a separate enclosure, intake and exhaust ventilation must be provided on the
enclosure, and the same operating guidelines listed above will still apply.

Temperature Range

Operating: 50° to 95° F (10° to 35° C)*

Non-operating: -22° to 140° F(-30° to 60° C)

Relative Humidity

Operating: 10% to 90% (non-condensing at ambient)

Non-operating: 5% to 95% (non-condensing at ambient)

Maximum Altitude (unpressurized)

Operating: 10,000 ft (3048 m)

Non-operating: 30,000 ft (9144 m)

*NOTE: Operating temperature is de-rated 1.0 deg C per 300 m (1000 ft) to 3000 m (10,000 ft) above sea level, no direct
sustained sunlight. Maximum rate of change is 10 deg C/Hr. The upper limit may be limited by the type and number of
options installed.

Microtower

Small Form Factor

Power Supply

300-watt BTX

power supply –

Passive PFC

115v/230v line

switch

300-watt 80 PLUS*

BTX power supply –

Active PFC

240-watt BTX

power supply –

Active PFC

115v/230v line

switch

240-watt 80 PLUS*

BTX power supply –

Active PFC

Operating Voltage Range

90 to 132VAC, or

180 to 264VAC

90 to 264VAC

90 to 132VAC, or

180 to 264VAC

90 to 264VAC

Rated Voltage Range

100 to 127VAC, or

200 to 240VAC

100 to 240VAC

100 to 127VAC, or

200 to 240VAC

100 to 240VAC

Rated Line Frequency

50/60 Hz

50/60 Hz

50/60 Hz

50/60 Hz

Operating Line Frequency Range

47–63 Hz

47–63 Hz

47–63 Hz

47–63 Hz

Rated Input Current

8A/4A

5A/2.5A

6A/3A

3.5A/1.75

Heat Dissipation

Typical 315 btu/hr

(79 kg-cal/hr)

Maximum 1575

btu/hr

(397 kg-cal/hr)

Typical 270 btu/hr

(68 kg-cal/hr)

Maximum 1280

btu/hr

(322 kg-cal/hr)

Typical 315 btu/hr

(79 kg-cal/hr)

Maximum

1260 btu/hr

(317 kg-cal/hr)

Typical 270 btu/hr

(68 kg-cal/hr)

Maximum 1025

btu/hr

(258 kg-cal/hr)

Power Supply Fan

Variable speed fan

Variable speed fan

Variable speed fan

Variable speed fan

ENERGY STAR 4.0 Compliant

X

X

FEMP Standby Power Compliant
(<2W in S5 – Power Off)**

X

X

X

X

Power Consumption in ES Mode –
Suspend to RAM (S3)
(Instantly Available PC)

<4W

<3W

<4W

<3W

QuickSpecs

HP Compaq dc5850 Business PC

Technical Specifications

DA - 12900 Worldwide QuickSpecs — Version 5 — 7.23.2008

Page 16