C. Install the Ceiling Firestop
A ceiling fi restop MUST be used between
fl oors and attics.
• Frame opening 9 in. x 9 in. (229 mm x
229 mm) whenever the vent penetrates
a ceiling/floor (see Figure 8.3).
• Frame the area with the same sized lumber
as used in ceiling/fl oor joist.
• The
ceiling
fi restop may be installed above
or below the ceiling joists when installed
with a attic insulation shield. It must be
under joists between fl oors that are not
insulated. Refer to Figure 8.4.
• Secure with three fasteners on each side.
WARNING! Risk of Fire! DO NOT pack
insulation around the vent. Insulation must be
kept back from the pipe to prevent overheat-
ing.