beautypg.com

Henny Penny CF-941 User Manual

Page 16

background image

Model CF-941

3-6. OPERATION AND

6. Press and release the SET button 4 times and “In-”

PROGRAMMING

shows in the display. In- means initialization. Press

(Continued)

and hold the UP or DOWN button at this time and

allow the display to count down from 3. The buzzer

will sound and the controls will be set at factory

settings.

7. Press and release the SET button 5 times and “OP”

will show in the display. OP means output test. Press

and release the drawer button to turn the relay and

heater off and on.

Press and hold the SET button to exit the Special

Program Mode at any time. Also, the controls will

automatically exit the Special Program Mode, if no

buttons are pressed for 1 minute.

3-7. ERROR CODES

DISPLAY

CAUSE

PANEL BOARD CORRECTION

E-4”

Control board

Turn switch to OFF position, then turn switch back to

overheating

ON; if display shows “E-4,” the control board is
getting too hot; make sure unit is not overheating

“E-6”

Wrong number of

Check to see if unit is set to the correct number of

drawers programmed, drawers, ex: MP-942=2 drawers (see programming

or faulty temperature

instructions); have temperature probe checked for

probe

faulty probe

“E-41”

Memory scrambled

Press and release the UP and DOWN buttons to

initialize the program; if “E-41” persists replace the

control board

“Hi”

Unit overheating;

Have relay or control board replaced

faulty relay or

con

trol

board

3-6