beautypg.com

Quickspecs – HP ProLiant PC2-6400 User Manual

Page 36

background image

Non-operating

9144 m (30,000 ft). Maximum allowable
altitude change rate is 457 m/min (1500
ft/min).

Acoustic Noise

Listed are the declared A-Weighted sound power levels (LWAd) and
declared average bystander position A-Weighted sound pressure levels
(LpAm) when the product is operating in a 23°C ambient environment.
Noise emissions were measured in accordance with ISO 7779 (ECMA
74) and declared in accordance with ISO 9296 (ECMA 109).

Idle

LWAd

6.30 B

LpAm

52.07dBA

Operating

LWAd

6.38 B

LpAm

52.77 dBA

Power Supply

Input voltage
specifications

Rated input voltage

100 VAC to 240 VAC

Input Specifications

Rated input line

90 VAC to 264VAC

Frequency range

47 to 63 Hz

Rated input power

@ 115V input, Rated input power = 486W
(assume output wattage=450W
@ 230V input, Rated input power = 479W
(assume output wattage=450W)

Rated input current

6 A, 3 A (110 V, 220 V)

Steady state power

420W (rated)

BTU Rating

1710 BTU/hr

Ambient temperature
range

Operating

50° to 118° F (10° to 48° C)

Non-operating

-40° to 158° F (-40° to 70° C)

Relative humidity
(non-condensing)

Operating

55% to 85%

Non-operating

5% to 95%

Dielectric voltage
withstand

Input to output

1800 VAC/minute

Input to ground

1800 VAC/minute

Maximum Wet Bulb
Temperature

106.3° F (41.3° C)

QuickSpecs

HP ProLiant DL320 Generation 5p

Technical Specifications

DA - 12854 Worldwide QuickSpecs — Version 12 — 5-28-2008

Page 36