beautypg.com

When troubles occur – haier AB212BCBAA User Manual

Page 22

background image

When Troubles Occur

Before contacting the commissioned repair center for after-sales service,
please check your air conditioner according to the following items.

Trouble display

E3

E5

Phenomenon of
outdoor unit trouble

The trouble of outdoor ambient
temperature sensor
The trouble of outdoor coil
temperature sensor
Over electric current protection
CT wire breaks

The flashing time of indicator light

on outdoor control panel

Indoor control

panel indication

1 (A, B systems indicate together)

The communication trouble
between indoor and outdoor unit

8 (A and B system indicate individually)

The trouble of outdoor coil
temperature sensor
The trouble of electric current
overload

2 (A and B system indicate individually)
5 (A and B system indicate individually)
6 (A and B system indicate individually)

E3

E4

E5

Symptom

Cause

Solution

The unit does not operate. The fuse is blown out or the breaker is open. Change the fuse or close the breaker.

Once the unit operates,

it stops immediately.

The air inlet or air outlet of indoor or outdo

or unit is blocked.

Remove the obstacles.

Abnormal of COOLING

or HEATING.

The air inlet or air outlet of indoor or outdo

or unit is blocked.

Remove the obstacles.

Improper set temperature

Referring to page 8

The fan speed is set too low

Referring to page 8

Incorrect swing direction

Referring to page 9

The doors or windows are open

Close them

Direct sunshine

Hang the curtain or blinds before

windows

Too much people in room
Too many heat sources in room

After checking the above items and treating the air conditioner, it still cannot
normally work, or find the following troubles occur, please stop the unit and
cut off power, then contact the after-sales service worker.
The fuse and creepage breaker are often blown out;
In Cooling or Dehumidifying operation, there is water leakage;
Abnormal operation or abnormal sound can be heard.

The screen on the wire controller shows trouble code (E1, …E0), which
indicates the air conditioner has trouble.

E8

The communication trouble

between panel and indoor panel

E2

The trouble of outdoor ambient
temperature sensor

Phenomenon of indoor

unit trouble

Trouble indication on remote

control type indoor unit

E5

E1

The trouble of indoor ambient

temperature sensor

The trouble of indoor coil
temperature sensor

E9

The communication trouble
between indoor panel and

outdoor panel

E0

The compressor indicator light flashes 10
time in 0.2S/time frequency

The trouble of water pump

E8

Trouble code on wire

control type indoor unit

The compressor indicator light flashes 1
time in 0.2S/time frequency

The compressor indicator light flashes 2
time in 0.2S/time frequency

The compressor indicator light flashes 3
time in 0.2S/time frequency

E4

The compressor indicator light flashes 5
time in 0.2S/time frequency

The compressor indicator light flashes 4
time in 0.2S/time frequency

The compressor indicator light flashes 8
time in 0.2S/time frequency

The compressor indicator light flashes 9
time in 0.2S/time frequency

20

This manual is related to the following products: