beautypg.com

C. location, D. setup, C. location d. setup – Hoshizaki KM-1900SAH/3 User Manual

Page 15

background image

15

C. Location

CAUTION

1. This icemaker is not intended for outdoor use. Normal operating ambient

temperature should be within 45°F to 100°F (7°C to 38°C); Normal operating
water temperature should be within 45°F to 90°F (7°C to 32°C). Operation
of the icemaker, for extended periods, outside of these normal temperature
ranges may affect icemaker performance.

2. This icemaker will not work at sub-freezing temperatures. To prevent damage

to the water supply line, drain the icemaker if the air temperature is going to
go below 32°F (0°C). See "III.C. Preparing the Icemaker for Long Storage."

For best operating results:

• Icemaker should not be located next to ovens, grills, or other high heat producing

equipment.

• Location should provide a firm, level foundation for the equipment.
• Allow 6" (15 cm) clearance at rear, sides, and top for proper air circulation and ease of

maintenance and/or service should they be required.

D. Setup

CAUTION

Before operating the icemaker, the bin control thermostat assembly must be
installed correctly. Failure to properly install the assembly could result in ice
backup and unit damage.

1) Unpack the storage bin, then attach the 4 adjustable legs provided (bin accessory) to

the bottom of the storage bin.

2) Position the storage bin in the selected permanent location.
3) Place the icemaker on top of the storage bin.
4) Secure the icemaker to the storage bin

using the 2 mounting brackets and the
bolts provided. See Fig. 2.

5) Level the icemaker/storage bin in both the

left-to-right and front-to-rear directions.
Adjust the storage bin legs to make the
icemaker level.

Fig. 2

Icemaker

Bolts

Mounting

Brackets

Bin

This manual is related to the following products: