beautypg.com

Important safety requirements, Location, An air vent of effective area of 110 cm – Electrolux 95752 G User Manual

Page 12: And 10 m, An air vent of effective area of 50 cm, Is required, while if the volume exceeds 11 m, And 11 m

background image

12

700 mm

400 mm

400 mm

100 mm

50 mm

50 mm

55 mm

700 mm

400 mm

100 mm

400 mm

50 mm

50 mm

55 mm

CLEARANCES REQUIRED WHEN FITTING THE GAS HOB

WITHOUT A COOKER HOOD ABOVE

CLEARANCES REQUIRED WHEN FITTING THE GAS HOB

WITH A COOKER HOOD ABOVE

FO 2028*

FO 2027*

Important safety requirements

This hob must be installed in accordance with the Gas Safety (Installation and Use)

Regulations (Current Edition) and the IEE Wiring Regulations (Current Edition).

Detailed recommendations are contained in the following British Standards Codes Of

Practice: B.S. 6172/ B.S. 5440, Par. 2 and B.S. 6891 Current Editions.

The hob should not be installed in a bed sitting room with a volume of less than 20 m

3

. If

it is installed in a room of volume less than 5 m

3

an air vent of effective area of 110 cm

2

is

required. If it is installed in a room of volume between 5 m

3

and 10 m

3

an air vent of

effective area of 50 cm

2

is required, while if the volume exceeds 11 m

3

no air vent is

required.

However, if the room has a door which opens directly to the outside no air vent is required

even if the volume is between 5 m

3

and 11 m

3

.

If there are other fuel burning appliances in the same room, B.S. 5440 Part 2 Current

Edition, should be consulted to determine the requisite air vent requirements.

Location

The hob may be located in a kitchen, a kitchen/diner or bed sitting room, but not in a

bathroom, shower room or garage.

Before making the cut out in the worktop ensure that there is a minimum distance of 55

mm. between the rear edge of the hob and the wall.

A minimum distance of 100 mm. must be left between the side edges of the hob and any

adjacent cabinets or walls. The minimum distance combustible material can be fitted

above the hob in line with the edges of the hob is 400 mm. If it is fitted below 400 mm. a

space of 50 mm. must be allowed from the edges of the hob. The minimum distance

combustible material can be fitted directly above the hob is 700 mm.