Model BL-69524ENT
Mid-Span Power Hub 24-Port User’s Guide A-3
Electrical Specifications
AC Power Input
DC Port Power Output
Voltage
90–264 V autoranging (46 Hz–63 Hz)
Connector
3-pin with ground
Chassis grounding
yes
Power supply
single
Power enabling
IEEE 802.3af
Power pins
Unused pairs, pins 4,5(+), 7,8(-)
Maximum power/port
15.6 W
Maximum power, all ports active
24 ports at 15.6 W each
Module-to-module isolation
1500 V RMS
Overload protection
If current reaches 400–450 mA for 300–400
milliseconds, then the port shuts down.
See also other documents in the category Enterasys Networks Computer Accessories:
- Enterasys RoamAbout RBT-1002-EU (28 pages)
- BL-89710ENT (28 pages)
- Enterasys Gold Distributed Forwarding Engine 4G4205-72 (100 pages)
- VH-8G-L3 (41 pages)
- 2H252-25R (64 pages)
- 6H302-48 (58 pages)
- ENTERASYS ATX (82 pages)
- CSX7000 (729 pages)
- Enterasys Matrix 9033989-06 (90 pages)
- Enterasys D2 D2G124-12 (496 pages)
- Enterasys Matrix 6H352-25 (56 pages)
- 5G1XX (144 pages)
- 2S4082-25-SYS (108 pages)
- 2200 (330 pages)
- Enterasys Gold Distributed Forwarding Engine 4H4202-72 (90 pages)
- 6000 (231 pages)
- 6E2xx (430 pages)
- D-Series (540 pages)
- Enterasys Matrix DFE-Gold Series (90 pages)
- Enterasys Vertical Horizon VH-2402S2 (7 pages)
- VH-2402S (58 pages)
- Enterasys SecureStack B2 B2G124-24 (80 pages)
- Enterasys Matrix C1H124-48 (64 pages)
- 2G4072-52 (70 pages)
- Enterasys Diamond Distributed Forwarding Engine 7KR4297-02 (64 pages)
- 2000 (188 pages)
- Enterasys Vertical Horizon VH-8G (48 pages)
- V2H124-24P (68 pages)
- Enterasys Platinum Distributed Forwarding Engine 7G4205-72 (96 pages)
- Enterasys SecureStack A2 A2H124-48P (82 pages)
- VH-4802 (56 pages)
- A2H124-24FX (82 pages)
- 700 (182 pages)
- C2K122-24 (70 pages)