Enviro C-10100 User Manual
Page 5
B) PIEZO IGNITOR OK BUT PILOT WILL STILL NOT LIGHT
Make sure all gas lines have
been connected with no
leaks.
Make sure that the gas is
“ON” (NG) Natural gas and
(LP) Propane tanks are full.
Make sure the appliance
service valve is in the “ON”
position.
SEE PAGE 4 FIGURE 3.
Test to make sure there is no
air in the gas line.
SEE PAGE 4 FIGURE 3.
Make sure that the valve has
not reset itself.
(All valves have an interlock
safety device.)
Make sure pilot injector is
not clogged.
Clean the pilot injector if
necessary.
Wait 60 seconds for the
safety to reset itself.
Use a match to see if air or
gas comes from the pilot
assembly.
Turn service valve to the
“ON” position.
Correct if necessary.
Correct if necessary, test
for gas leaks in an
approved manner.
Sherwood Industries Ltd.
ENVIRO
PAGE 3