beautypg.com

B) direct vent models – Enviro C-10100 User Manual

Page 20

background image

B) DIRECT VENT MODELS

Check air shutter on the

burner tube (venturi).

Adjust air shutter.

Close until flame sits onto

the burner ports.

Seal exhaust tube with high

temperature silicone.

Also make sure that

combustion air pipe is

sealed.

Make sure there are no leaks

in the venting system.

Make sure the unit is not

recirculating flue products.

Check flue for blockage or

high wind situations.

Use a manometer to check

gas outlet (manifold)

pressure.

SEE PAGE 5 FIGURE 7.

Make sure the gas pressure

is correct for fuel being used.

Make sure the orifice size is

the same as the rating plate.

Correct if necessary.

Add a vent restrictor ring.

SEE OWNERS MANUAL.

Only if necessary.

Sherwood Industries Ltd.

ENVIRO

PAGE 18