beautypg.com

5) sooting – Enviro C-10100 User Manual

Page 17

background image

5) SOOTING

Make sure log placement is

in the correct location.

Correct to manufactures

specifications.

Correct if necessary.

Outside air supply may be

required on B-vented

models.

Make sure there is sufficient

air supply.

Check air shutter on the

venturi tube for proper

primary air adjustment.

SEE PAGE 16.

Increase primary air.

Open air shutter.

Make sure orifice matches

that on the rating plate.

Correct if necessary.

Make sure outlet (manifold)

pressure is correct.

Use a manometer to check

the gas pressure.

SEE PAGE 5 FIGURE 7.

Make sure the unit has been

derated for high altitude

applications.

(if required)

Correct if necessary.

Check to make sure that the

vent is drafting properly.

Correct if necessary.

Sherwood Industries Ltd.

ENVIRO

PAGE 15