Specifications, Installation requirements, Electrical requirements – Wolf 36 Inch Cooktop Installation Guide User Manual
Page 4
![background image](https://www.manualsdir.com/files/894266/content/doc004.png)
4 | Wolf Customer Care 800.222.7820
Installation Requirements
A minimum 2"
(51)
is required from the bottom of the
cooktop to combustible materials. If the cooktop is
installed above an oven, a minimum of 1/4"
(6)
is required
between the units.
The Contemporary gas cooktop can be mounted flush
with the top of the countertop or as a standard installation
sitting on top of the countertop surface. If the cooktop is
to be mounted flush with the countertop, a recessed area
surrounding the cooktop cutout must be provided. The
countertop must be able to withstand temperatures up to
300°F
(149°C)
.
IMPORTANT NOTE:
For flush installations, do not use the
cooktop as a template to create the countertop open-
ing. Use the countertop cutout template or specifications
provided. Failure to do so may cause damage.
Specifications
Electrical Requirements
Installation must comply with all applicable electrical codes.
Locate the electrical supply as shown in the illustrations
on the following pages. A separate circuit servicing only
this appliance is required. A ground fault circuit interrupter
(GFCI) is not recommended and may cause interruption of
operation.
ELECTRICAL REQUIREMENTS
Electrical Supply
grounded, 120 VAC, 60 Hz
Service
15 amp dedicated circuit
Receptacle
3-prong grounding-type
Power Cord
6'
(1.8 m)