3

Cabinet Dimensions

IMPORTANT:

If installing a range hood or microwave hood

combination above cooking surface, follow the range hood or

microwave hood combination installation instructions for

dimensional clearances above the cooktop surface.

NOTES:

After making the countertop cutout, some installations

may require notching down the base cabinet side walls to clear

the cooktop base. To avoid this modification, use a base cabinet

with sidewalls wider than the cutout.
If cabinet has a drawer, a 5¹⁄

2

" (14.0 cm) depth clearance from

the top of the countertop to the top of the drawer (or other

obstruction) in base cabinet is required.

Electrical Requirements

If codes permit and a separate ground wire is used, it is

recommended that a qualified electrical installer determine that

the ground path and wire gauge are in accordance with local

codes.
Check with a qualified electrical installer if you are not sure the

cooktop is properly grounded.
Make sure that the electrical connection and wire size are

adequate and in conformance with the National Electrical Code,

ANSI/NFPA 70-latest edition or CSA Standards C22.1-94,

Canadian Electrical Code, Part 1 and C22.2 No. O-M91-latest

edition, and all local codes and ordinances.

A copy of the above code standards can be obtained from:

National Fire Protection Association

1 Batterymarch Park

Quincy, MA 02169-7471

CSA International

8501 East Pleasant Valley Road

Cleveland, OH 44131-5575

Before You Make the Electrical Connection:

To properly install your cooktop, you must determine the type of

electrical connection you will be using and follow the instructions

provided for it here.
A 3-wire or 4-wire, single phase, 120/240 volt, 60-Hz., AC only

electrical supply is required on a separate, 40-amp circuit fused

on both sides of the line. The model/serial number rating plate is

located on the metal cabinet underneath the cooktop.

See the following illustration.

The cooktop is rated 120/240 volt. Some models have a

neutral (white) wire.

D

A

E

I

J

K

G

H

L

C

F

B

A. 24" (60.9 cm) on 24" models; 30" (76.2 cm) on 30" models;

36" (91.4 cm) on 36" models

B. Combustible area above countertop (shown by dashed box above)
C. 30" (76.2 cm) minimum clearance between top of cooktop

platform and bottom of uncovered wood or metal cabinet

(24" [61 cm] minimum clearance if bottom of wood or metal

cabinet is covered by not less than ¹⁄

4

"[0.6 cm] flame retardant

millboard covered with not less than No. 28 MSG sheet steel,

0.015" [0.04 cm] stainless steel, or 0.024” [0.06 cm] aluminum

or 0.020" [0.05 cm] copper)

D. 13" (33 cm) recommended upper cabinet depth
E. 2" (5.1 cm)
F. 20¹⁄

2

" (52.0 cm) recommended cutout.

Will fit in cutout from 20³⁄

8

"-20

9

16

" (51.8-52.2 cm).

G. 18" (45.7 cm) minimum clearance from upper cabinet to

countertop within minimum horizontal clearances to cooktop

H. Junction box or outlet: 7" (17.8 cm) minimum from top of

countertop

I. Junction box or outlet: 9" (23.0 cm) maximum from right side

of cabinet

J. 29¹⁄

2

" (74.9 cm) recommended cutout on 30" (76.2 cm) models.

Will fit in cutout from 29 ¹⁄

16

"-29

9

16

" (73.8-75.1 cm) on 30"

(76.2 cm) models.

35¹⁄

2

" (90.2 cm) recommended cutout on 36" (91.4 cm) models.

Will fit in cutout from 34

9

16

"-35

9

16

" (87.8-90.3 cm) on

36"(91.4 cm) models.

22

5

/

16

" (56.67 cm) recommended cutout on 24" (60.96 cm)

K. 2

1

/

2

" (6.35 cm) minimum distance to nearest left and right side

combustible surface above cooktop

L. 1

1

/

2

" (3.81 cm) minimum clearance between back wall and

countertop

WARNING

Electrical Shock Hazard

Disconnect power before servicing.
Use 8 gauge copper wire.
Electrically ground cooktop.
Failure to follow these instructions can result in death,

fire, or electrical shock.

A

A. Model/serial number plate