INSTALLATION REQUIREMENTS

Tools and Parts

Gather the required tools and parts before starting installation.

Read and follow the instructions provided with any tools listed

here.

Tools needed

Tape measure

1

/

4

" (6.35 mm) cnut driver

Marker or pencil

Pliers

Flat-blade screwdriver

Parts supplied

Foam strip roll

Clamping brackets (2)

2½" (6.4 cm) clamping

screws (2)

Parts needed

A UL listed or CSA approved connector for ½" (1.3 cm)

diameter conduit

UL listed wire connectors

Check local codes. Check existing electrical supply. See the

“Electrical Requirements” section.
It is recommended that all electrical connections be made by a

licensed, qualified electrical installer.

Location Requirements

IMPORTANT:

Observe all governing codes and ordinances.

When installing cooktop, use minimum dimensions given.

To eliminate the risk of burns or fire by reaching over the

heated surface units, cabinet storage space located above

the surface units should be avoided. If cabinet storage is to

be provided, the risk can be reduced by installing a range

hood that projects horizontally a minimum of 5” (12.7 cm)

beyond the bottom of the cabinets.

The cooktop must be a specified cooktop that is approved

to be installed either alone or over an undercounter built-in

oven. Check the cooktop base for an approved installation

label. If you do not find this label, contact your dealer to

confirm that your cooktop is approved.

The cooktop must be installed in a level countertop.

Ovens approved for this type of installation will have an

approval label located on the top of the oven. If you do

not find this label, contact your dealer to confirm that your

oven is approved. Refer to oven manufacturer’s Installation

Instructions for approval for built-in undercounter use and

proper cutout dimensions.

The cooktop should be installed away from strong draft

areas, such as windows, doors, fans or strong heating vents.

The cooktop should be located for convenient use in the

kitchen.

Use the countertop opening dimensions that are given

with these Installation Instructions. Given dimensions are

minimum clearances and provide 0" (0 cm) clearance.

Grounded electrical supply is required. See “Electrical

Requirements” section.

IMPORTANT:

To avoid damage to your cabinets, check with

your builder or cabinet supplier to make sure that the materials

used will not discolor, delaminate, or sustain other damage.

Product Dimensions

A

B

D

F

E

C

A. Glass depth - black and white models - 21 ³⁄

4

" (55.2 cm)

Glass depth - stainless steel models - 22 ¹⁄

8

" (56.4 cm)

B. Glass width - 24" (60.9 cm) models - 23

13

/

16

" (60.5 cm)

Glass width - 30" (76.2 cm) models - 30

13

/

16

" (78.4 cm)

Glass width - 36" (91.4 cm) models - 36

5

/

16

" (92.3 cm)

C. Frame depth - 20¹⁄

4

" (51.5 cm)

D. Frame width - 24" (60.9 cm) models - 21

59

/

64

" (55.7 cm)

Frame width - 30" (76.2 cm) models - 28

15

/

16

" (73.5 cm)

Frame width - 36" (91.4 cm) models - 34

7

/

16

" (87.5 cm)

E. Cooktop height - 3

3

4

" (9.6 cm)

Cooktop height lighted knobs - 30" (76.2 cm) models -

4

15

/

16

" (12.55 cm)

Cooktop height lighted knobs - 36" (91.4 cm) models -

4

15

/

16

" (12.55 cm)

F. Cooktop height including conduit (located at rear of cooktop, right

side) - 5

1

4

” (13.5 cm)

Cooktop height lighted knobs, including conduit (located at rear of

cooktop, right side) - 30" (76.2 cm) models - 5

5

/

16

" (13.5 cm)

Cooktop height lighted knobs, including conduit (located at rear of

cooktop, right side) - 30" (76.2 cm) models - 5

5

/

16

" (13.5 cm)