Gas Supply Line

Provide a gas supply line of ³⁄

4

” (19 mm) rigid pipe to the

cooktop location. A smaller size pipe on longer runs may

result in insufficient gas supply. Pipe-joint compounds that

resist the action of Propane gas must be used. Do not

use TEFLON

®

† tape. With Propane gas, piping or tubing

size should be ½” (13 mm) minimum. Usually, Propane

gas suppliers determine the size and materials used in the

system.

Flexible metal appliance connector:

If local codes permit, use a ¹⁄

2

” (13 mm) or ³⁄

4

” (19 mm)

I.D. flexible stainless steel tubing gas connector,

designed by CSA to connect the cooktop to the rigid gas

supply line.

A

1

/

2

" (13 mm) male pipe thread is needed for connection

to the female pipe threads of the inlet to the cooktop

pressure regulator.

Do not kink or damage the flexible metal tubing when

moving the cooktop.

Must include a shutoff valve:

Install a manual gas line shut-off valve in an easily accessible

location. Do not block access to shut-off valve. The valve is

for turning on or shutting off gas to the cooktop.

Gas Pressure Regulator

The gas pressure regulator supplied with this cooktop must be

used. The inlet pressure to the regulator should be as follows for

proper operation:

Natural Gas:

Minimum pressure: 5” (12.7 cm) WCP
Maximum pressure: 7” to 14” (17.8 cm to 35.5 cm) WCP

Propane Gas:

Minimum pressure: 10” (25.4 cm) WCP
Maximum pressure: 14” (35.5 cm) WCP
Contact local gas supplier if you are not sure about the inlet

pressure.

Burner Input Requirements

Input ratings shown on the model/serial rating plate are for

elevations up to 2,000 ft (609.6 m).
For elevations above 2,000 ft (609.6 m), ratings should be

reduced at a rate of 4% for each 1,000 ft (304.8 m) above sea

level (not applicable for Canada).

Gas Supply Pressure Testing

Gas supply pressure for testing regulator must be at least 1”

(2.5 cm) water column pressure above the manifold pressure

shown on the model/serial rating plate.

Line pressure testing above

1

/

2

psi (3.5 kPa) gauge

(14” [35.5 cm] WCP)

The cooktop and its individual shutoff valve must be

disconnected from the gas supply piping system during any

pressure testing of that system at test pressures in excess of

½ psi (3.5 kPa)

Line pressure testing at ½ psi (3.5 kPa) gauge

(14” [35.5 cm] WCP) or lower

The cooktop must be isolated from the gas supply piping system

by closing its individual manual shutoff valve during any pressure

testing of the gas supply piping system at test pressures equal

to or less than ½ psi (3.5 kPa).

A

B

C

A. Gas supply line
B. Shut off valve open position
C. To cooktop

®