beautypg.com

Whirlpool 30 Inch Gas Cooktop Installation Guide User Manual

Page 10

background image

10

3.

Use a

15

16

” (24 mm) combination wrench and channel lock

pliers to attach the flexible connector to the adapters. Check

that connector is not kinked.

IMPORTANT:

All connections must be wrench-tightened. Do

not make connections to the gas regulator too tight. Making

the connections too tight may crack the regulator and cause

a gas leak. Do not allow the regulator to turn when tightening

fittings.

4.

Install the pressure regulator with the arrow pointing in the

direction toward the bottom of the cooktop base and in a

position where you can reach the regulator access cap.

Use only pipe-joint compound made for use with Natural and

Propane gas.
Do not use TEFLON

®

tape. You will need to determine the fittings

required depending on your installation.

Complete Connection

1.

Open the manual shutoff valve in the gas supply line. The

valve is open when the handle is parallel to the gas pipe.

2.

Test all connections by brushing on an approved

noncorrosive leak-detection solution. Bubbles will show a

leak. Correct any leak found.

3.

Remove surface burner caps, burner base and grates from

parts package. Align notches in burner caps with pins in

burner base.
Align orifice holder in burner base with igniter electrode.

Burner caps should be level when properly positioned. If

burner caps are not properly positioned, surface burners will

not light. Place burner grates over burners and caps.

A

B

C

D

A. Access cap
B. Rear of cooktop
C. Gas pressure regulator
D. Up arrow. The regulator must be installed with

arrow pointing up to cooktop bottom

No appliance/obstructions

below cooktop

A

B

D

E

C

F

G

H

I

Suggested installation to

avoid interference below

cooktop

A

B

C

D

F

I

J

K

H

E

G

A. Manifold entrance
B. Gas pressure regulator
C. Use pipe-joint compound.
D. Adapter (must have ½”

[13 mm] male pipe thread)

E. Flexible connector
F. Adapter
G. Use pipe-joint compound.
H. Manual gas shut-off valve
I. ½” (13 mm) or ¾” (19 mm) gas

pipe

A. Manifold entrance
B. ³⁄

8

” (10 mm) elbow

C. Use pipe-joint compound.
D. Adapter (must have ³⁄

8

” [10

mm] male pipe thread)

E. Flexible connector (pass

through wall between cabinets)

F. Adapter (must have ³⁄

8

” [10

mm] male pipe thread)

G. Use pipe-joint compound.
H. Appliance pressure regulator

(supplied)

I. ½” (13 mm) or ¾” (19 mm) gas

pipe

J. Manual gas shutoff valve
K. ½” (13 mm) or ¾” (19 mm) gas

pipe

A

B

B

C

D

E

A

A. Orifice holder
B. Burner cap
C. Gas tube opening
D. Burner base
E. Igniter electrode