Impor

tant saf

ety inf

ormation

Electrical service to the range must conform to local codes. Barring local
codes, it should meet the latest ANSI/NFPA No. 70 – Latest Revision (for the
U.S.) or the Canadian Electrical Code CSA C22.1 – Latest Revisions.

It is the personal responsibility of the range owner to provide the correct
electrical service for this range.

Installation safety

WARNING

To reduce the risk of fire, electric shock, personal injuries, and/or death, obey the
following precautions.

Have your range installed and
properly grounded by a

qualified

installer

, in accordance with the

installation instructions. Any
adjustment and service should
be performed only by qualified
gas range installers or service
technicians.

Do not attempt

to service, modify, or replace your range or any part of your

range unless it is specifically recommended in this manual. All other service
should be referred to a qualified technician.

Always use new flexible connectors when installing a gas appliance.

Do not

use

old flexible connectors.

Make sure

the anti-tip device is properly installed on the range. See the

installation instructions for more information.

Due to the size and weight of the range, have

two or more people

move the

range.

Remove

all tape and packaging materials.

Remove

all accessories from the cooktop and oven. Grates are heavy. Use

caution when handling them.

Make sure

no parts came loose during shipping.

Electrical and grounding safety

WARNING

To reduce the risk of fire, electric shock, personal injuries, and/or death, obey the
following precautions.

Plug into a grounded 3-prong outlet.

Do not remove

the ground prong.

Do not use

an adapter or an

extension cord.

Do not use

a damaged power plug,

power cord, or loose power outlet.

Do not modify

the power plug,

power cord, or power outlet in any
way.

Do not put

a fuse in a neutral or ground circuit.

Use a dedicated 120-volt, 60-Hz, 10-amp, AC, fused electrical circuit for this
range. A time-delay fuse or circuit breaker is recommended. Do not plug more
than one appliance into this circuit.

Do not connect

the ground wire to plastic plumbing lines, gas lines, or hot

water pipes.

This range

must be Earth grounded

. In the event of a malfunction or

breakdown, grounding will reduce the risk of electrical shock by providing
a path for the electric current. This range is equipped with a cord having
a grounding plug. The plug must be firmly plugged into an outlet that is
properly installed and grounded in accordance with the local codes and
ordinances. If you are unsure whether your electrical outlet is properly
grounded, have it checked by a licensed electrician.

The range is supplied with a 3-pronged grounded plug. This cord must
be plugged into a grounded 3-prong outlet that meets all local codes and
ordinances. If codes permit the use of a separate ground wire, we recommend
that a qualified electrician determine the proper path for this ground wire.