beautypg.com

Installation instructions – Dacor Transitional 36 Inch Freestanding Gas Smart Range Install Guide User Manual

Page 20

background image

20 English

Ins
tallation ins

truc

tions

Installation instructions

Flexible connector hookup

Installer: Inform the consumer of the location of the gas shut-off valve.

Pressure

Regulator

Adapter

Flex Connector

(6-ft max.)

Adapter

Gas Shut-Off Valve

0.5 in or 0.75 in Gas Pipe

Tubing Line to Oven
Burner Control Valve

Tubing Line to Cooktop
Control Manifold

Gas Flo

w int

o R

ange

NOTE

If your area requires a rigid pipe hookup, contact a qualified installer, service
agency, or gas supplier.

The gas shut-off valve should be installed in an accessible location in the gas
piping, external to the appliance, for the purpose of turning on or shutting off
the gas to the appliance.

To prevent gas leaks, apply pipe-joint compound or wrap pipe-thread tape
with Teflon on all male (external) pipe threads.

1.

Install a manual gas line shut-off valve in the gas line in an easily
accessed location outside of the range.
Make sure everyone operating the range knows where and how to shut
off the gas supply to the range.

2.

Install male 0.5 in (1.3 cm) flare union adapter to the 0.5 in (1.3 cm)
NPT internal thread at the regulator inlet. Use a backup wrench on the
regulator fitting to avoid damage.
When installing the range from the front, remove the 90° elbow for easier
installation.

3.

Install male 0.5 in (1.3 cm) or 0.75 in (1.9 cm) flare union adapter to the
NPT internal thread of the manual shut-off valve, taking care to back up
the shut-off valve to keep it from turning.

4.

Connect flexible metal appliance connector to the adapter on the range.
Position range to permit connection at the shut-off valve.

5.

When all connections have been made, make sure all range controls are in
the off position and turn on the main gas supply valve. Use a liquid leak
detector at all joints and connections to check for leaks in the system.

WARNING

Do not use a flame to check for gas leaks to prevent death, personal injury,
explosion, and/or fire hazard.

When using test pressures greater than 1/2 psig to pressure-test the gas supply
system of the residence, disconnect the range and individual shut-off valve
from the gas supply piping. When using test pressures of 1/2 psig or less to test
the gas supply system, simply isolate the range from the gas supply system
by closing the individual shut-off valve.

WARNING

Do not exceed 25 ft-lbs of torque when making gas line connections.
Overtightening may crack the pressure regulator resulting in gas leak.