Installation requirements
13 in (33 cm)
Overhead
Cabinet Depth
0 in (0 cm)
22.6 in
(573.5 mm)
24 in
(61 cm) Lower
Cabinet Depth
6 in*
(15.2 cm)
6 in*
(15.2 cm)
37 1/2 in
(953 mm)
36 in
(914 mm)
18 in
(45.7 cm)
30 in (76.2 cm)
30 in (76.2 cm)
0 in (0 cm)
Clearance Below
Cooking Top
and at Rear and
Sides of Range
48 in
(121.9 cm)
Minimum to
combustibles
(Installation
without a
hood)
* Side clearance above cooking surface to any objects, i.e., wall.
Installation requirements
Location requirements
Clearances and dimensions
NOTE
•
For OTR over Gas Stove, please follow local GAS CODE.
•
BEFORE YOU BEGIN
to install this appliance, refer to the following information,
dimensions, and clearances.
Do not locate the range where it may be subject
to strong drafts.
Provide adequate clearances between the range and adjacent
combustible surfaces. These dimensions must be met for safe use of the range.
The location of the electrical outlet and gas piping may be adjusted to meet
the following dimensions and clearances.
•
For installation in Canada, a free-standing range is not to be installed closer
than 4.7 in (12 cm) from any adjacent surface.
•
Installations without a hood require 48" minimum to combustibles. A custom
hood installation with exposed horizontal combustible surfaces must have
an Auto-On feature. Refer to hood installation instructions for specific hood
clearances.
CAUTION
This range has been designed to comply with the maximum allowable wood
cabinet temperature of 194 °F (90 °C). Make sure the wall covering, countertops,
and cabinets around the range can withstand the heat (up to 194 °F [90 °C])
generated by the range. If not, discoloration, delamination, or melting may occur.