Technical specifications, Installation, Unpacking – Electrolux CHDD 8820 User Manual
Page 12: Position, Electrical connection
![background image](/manuals/87350/12/background.png)
60
Technical Specifications
Modell
DD 8890
CHDD 8820
CHDD 8890
Dimensions - extractor version (in cm):
Height
70-113
68,5-113,4
Width
89,8
119,8
Depth
50
46
Dimensions - filter version (in cm):
Height
78-122
77,2 - 123
Width
89,8
119,8
Depth
50
46
Lighting:
2 x 20W
4 x 20 W
Grease filter:
3
4
Electrical connection:
220 - 240 V
240 V
Maximum absorbed power:
215 W
275 W
Installation
Unpacking
Check that the cooker hood is not damaged. Transportation damages
should immediately be reported to the transport company. Damages,
faults and missing parts should immediately be reported to the retailer.
Dispose carefully of the packaging material so that it is out of the way
of small children.
Position
The cooker hood should be mounted freely hanging on the wall. The
cooker hood must be at least 50 cm above electric hobs or electric
ranges, or at least 70 cm above gas burners or gas ranges.
The cooker hood cannot be connected to flues of other
appliances that run on energy sources other than electricity.
Please, keep to the provisions of official directives regarding fume
discharge.
Electrical connection
The hood has a power cable with earth connection and the rated voltage
is 220-240V.