12

INSTALLATION INSTRUCTIONS

Electrical connection information for electric dryers

For direct wire connections:

!

WARNING!

Fire Hazard

Use 10 gauge copper wire.

Use a UL-listed strain relief.

Disconnect power before making electrical connections.

Connect neutral wire (white or center wire) to center terminal.

Ground wire (green or bare wire) must be connected to green
ground connector.

Connect remaining two supply wires to remaining two terminals.

Securely tighten all electrical connections.

Replace the terminal block cover.

Failure to do so can result in death, fire or electrical shock.

Grounding instructions

For a permanently connected dryer:

This dryer must be connected to a grounded metal, permanent wiring system, or
an equipment-grounding conductor must be run with the circuit conductors and
connected to the equipment-grounding terminal on the appliance.

WARNING!

Improper connection of the equipment-grounding conductor can result in a risk
of electric shock. Check with a qualified electrician, or a Fisher & Paykel trained
and supported service technician if you are in doubt as to whether the appliance
is properly grounded.

SAVE THESE INSTRUCTIONS