HOOD EXHAUST

Note

: Read the next two pages only if you plan to vent your

exhaust to the outside. If you plan to recirculate the air back

into the room, proceed to page 5.
All ductwork must be metal. DO NOT use plastic duct. Check

that all connections are made securely.

OUTSIDE TOP EXHAUST

(EXAMPLE ONLY)

The following chart describes an example of one possible

ductwork installation.

DUCT PIECES

EQUIVALENT

LENGTH X

NUMBER USED

EQUIVALENT

LENGTH

Roof Cap

24 ft (7.3 m)

x 1

24 ft

(7.3 m)

12 ft (3.7 m)

Straight Duct

(6"/15.24 cm

Round)

12 ft (3.7 m)

x 1

12 ft

(3.7 m)

Rectangular-to-

Round

Transition

Adapter*

5 ft (1.5 m)

x 1

5 ft

(1.5 m)

Total Length 41 ft (12.5 m)

Equivalent lengths of duct pieces are based on actual tests

and reflect requirement for good venting performance with

any vent hood.

*IMPORTANT:

If a rectangular-to-round transition adapter

is used, cut the corners of the damper with tin snips to allow

free movement of the damper.

OUTSIDE REAR EXHAUST

(EXAMPLE ONLY)

The following chart describes an example of one possible

ductwork installation.

DUCT PIECES

EQUIVALENT

LENGTH X

NUMBER USED

EQUIVALENT

LENGTH

Wall Cap

40 ft (12.2 m)

x 1

40 ft

(12.2 m)

3 ft (91.4 cm)

Straight Duct

(3

1

/

4

" x 6"/

8.25 x 15.24 cm

Round)

3 ft (91.4 cm)

x 1

3 ft

(91.4 cm)

90˚ Elbow

10 ft (4 m)

x 2

20 ft

(6.1 m)

Total Length 63 ft (19.2

m)

Equivalent lengths of duct pieces are based on actual tests

and reflect requirement for good venting performance with

any vent hood.

Note:

To ensure adequate space for the exhaust, align

exhaust between wall-studs or designate a space to

accommodate exhaust between studs at the time of wall

construction.