THE MICROWAVE MUST BE LEVEL
Use a level to make sure the cabinet bottom is level. If
the cabinets have a front overhang only, with no back or
side frame, the top line of Rear Wall Template must align
with below cabinet bottom, the same distance as the front
overhang depth. This will keep the microwave level.
1.
Measure the inside depth of the front overhang.
2.
Draw a horizontal line on the back wall, an equal distance
below the cabinet bottom as the inside depth of the front
overhang.
3.
For this type of installation with front overhang only, align
top line of Rear Wall Template with this horizontal line,
not touching the cabinet bottom as described in step D.
Note:
Your cabinets may have decorative trim that interferes
with the microwave installation. Remove the decorative trim
to install the microwave properly and to make it level.
D. ALIGN TOP LINE OF REAR WALL TEMPLATE
Area E
Center line
CAUTION
Wear gloves to avoid cutting fingers on sharp
edges.
1.
Using tape measure, draw a vertical line on the wall at the
center of the 24" (61 cm) wide space.
2.
Tape the Rear Wall Template on the cabinet wall, align the
center markers on the Rear Wall Template to the center
line on wall, making sure it is level and that the top line of
the Rear Wall Template is butted up against the bottom
edge of the upper cabinet.
3.
While taping the Rear Wall Template on the wall, draw
circles on the wall at hole A, B, C (see illustration above/
actual plate marked with arrows). THREE HOLES MUST
BE USED FOR MOUNTING. (If there are 2 wall studs in
right and left side based on center line, four holes must
be used for mounting.)
4.
Remove the Rear Wall Template and check the marking
based on the actual mounting plate (center line, holes
A, B, C).
5.
Drill holes on the circle marks (A, B, C). Drill a
3
/
16
" (4.7
mm) hole at C for lag screw and two
5
/
8
" (15.88 mm) holes
at A and B for toggle bolts.
Note:
DO NOT MOUNT THE PLATE AT THIS TIME.
6.
If the Rear Wall Template is damaged or unusable, mea-
sure and mark the wall with the dimensions described in
step E.
E. MARK REAR WALL OF THE CABINET WITHOUT
REAR WALL TEMPLATE
1.
The bottom edge line of Mounting Plate must be 17
1
/
8
"
(435 mm) from the bottom edge line of upper cabinet and
must be level.
2.
Mounting plate end holes must be 16
11
/
16
" (423.8 mm)
from the bottom edge line of upper cabinet and must be
on a equal line with each other. They must each be 9
3
/
8
"
(237.8 mm) from the center line.
Bottom edge line of upper cabinet
Mounting plate end hole
(right/left)
16
11
/
16
"
(423.8 mm)
17
1
/
8
"
(435 mm)
Bottom edge line of
mounting plate
9
3
/
8
"
(237.8 mm)
9
3
/
8
"
(237.8 mm)
INSTALLATION TYPES
(CHOOSE A, B OR C)
This microwave oven is designed for adaptation to the fol-
lowing three types of ventilation:
A. OUTSIDE TOP EXHAUST (VERTICAL DUCT)
See page 12.
Adapter in place
for outside top exhaust
B. OUTSIDE REAR EXHAUST (HORIZONTAL DUCT)
See page 14.
STEP-BY-STEP INSTALLATION GUIDE
3
12 / 24 EN
Over The Range Microwave Oven / Installation Manual