THE MICROWAVE MUST BE LEVEL

Use a level to make sure the cabinet bottom is level. If

the cabinets have a front overhang only, with no back or

side frame, the top line of Rear Wall Template must align

with below cabinet bottom, the same distance as the front

overhang depth. This will keep the microwave level.

1.

Measure the inside depth of the front overhang.

2.

Draw a horizontal line on the back wall, an equal distance

below the cabinet bottom as the inside depth of the front

overhang.

3.

For this type of installation with front overhang only, align

top line of Rear Wall Template with this horizontal line,

not touching the cabinet bottom as described in step D.

Note:

Your cabinets may have decorative trim that interferes

with the microwave installation. Remove the decorative trim

to install the microwave properly and to make it level.

D. ALIGN TOP LINE OF REAR WALL TEMPLATE

Area E

Center line

CAUTION

Wear gloves to avoid cutting fingers on sharp

edges.

1.

Using tape measure, draw a vertical line on the wall at the

center of the 24" (61 cm) wide space.

2.

Tape the Rear Wall Template on the cabinet wall, align the

center markers on the Rear Wall Template to the center

line on wall, making sure it is level and that the top line of

the Rear Wall Template is butted up against the bottom

edge of the upper cabinet.

3.

While taping the Rear Wall Template on the wall, draw

circles on the wall at hole A, B, C (see illustration above/

actual plate marked with arrows). THREE HOLES MUST

BE USED FOR MOUNTING. (If there are 2 wall studs in

right and left side based on center line, four holes must

be used for mounting.)

4.

Remove the Rear Wall Template and check the marking

based on the actual mounting plate (center line, holes

A, B, C).

5.

Drill holes on the circle marks (A, B, C). Drill a

3

/

16

" (4.7

mm) hole at C for lag screw and two

5

/

8

" (15.88 mm) holes

at A and B for toggle bolts.

Note:

DO NOT MOUNT THE PLATE AT THIS TIME.

6.

If the Rear Wall Template is damaged or unusable, mea-

sure and mark the wall with the dimensions described in

step E.

E. MARK REAR WALL OF THE CABINET WITHOUT

REAR WALL TEMPLATE

1.

The bottom edge line of Mounting Plate must be 17

1

/

8

"

(435 mm) from the bottom edge line of upper cabinet and

must be level.

2.

Mounting plate end holes must be 16

11

/

16

" (423.8 mm)

from the bottom edge line of upper cabinet and must be

on a equal line with each other. They must each be 9

3

/

8

"

(237.8 mm) from the center line.

Bottom edge line of upper cabinet

Mounting plate end hole

(right/left)

16

11

/

16

"

(423.8 mm)

17

1

/

8

"

(435 mm)

Bottom edge line of

mounting plate

9

3

/

8

"

(237.8 mm)

9

3

/

8

"

(237.8 mm)

INSTALLATION TYPES

(CHOOSE A, B OR C)

This microwave oven is designed for adaptation to the fol-

lowing three types of ventilation:

A. OUTSIDE TOP EXHAUST (VERTICAL DUCT)

See page 12.

Adapter in place

for outside top exhaust

B. OUTSIDE REAR EXHAUST (HORIZONTAL DUCT)

See page 14.

STEP-BY-STEP INSTALLATION GUIDE

3

12 / 24 EN

Over The Range Microwave Oven / Installation Manual