C. RECIRCULATING (NON-VENTED DUCTLESS)

See page 18.

A. OUTSIDE TOP EXHAUST (VERTICAL DUCT) DEFAULT

Installation overview
A1. Attach the mounting plate to the wall
A2. Use Top Cabinet Template for preparation of top cabinet
A3. Check for proper damper operation
A4. Mount the microwave oven
A5. Adjust the exhaust adapter
A6. Connect ductwork

A1.

ATTACH MOUNTING PLATE TO THE WALL

Attach the mounting plate to the wall using the wing nuts and

toggle bolts. At least one lag screw must be used to attach

the mounting plate to a wall stud.

1.

Insert the toggle bolts into the mounting plate through the

holes designed to go into drywall and attach the wing nuts

to

3

4

" (1.9 cm) onto each toggle bolt.

2.

Place the mounting plate against the wall and insert the

wing nuts into the holes in the wall to mount the plate.

CAUTION

Be careful to avoid pinching fingers

between the back of the mounting plate and the wall.

3.

Tighten all bolts. Pull the mounting plate away from the

wall to help tighten the bolts.

5

/

8

"

Wall

Toggle

Bolt

Wing nut

Bolt end

Spacing for toggles more

than wall thickness

STEP-BY-STEP INSTALLATION GUIDE

3

13 / 24 EN

Over The Range Microwave Oven / Installation Manual