a

Commissioning

When the hob has been fully installed it will be necessary

to check the minimum flame setting. To do this, follow

the procedure below.
- Turn the gas tap to the MAX position and ignite.
- Set the gas tap to the MIN flame position then turn

the control knob from MIN to MAX several times. If

the flame is unstable or is extinguished follow the

procedure below.

Procedure:

Re-ignite the burner and set to MIN.

Remove the control knob.

The adjustment screw is located down the centre

of the gas tap control shaft or on the lower right

hand side of the shaft (see diagram).

To adjust, use a thin bladed screwdriver and turn

the adjustment screw until the flame is steady

and does not extinguish, when the knob is turned

from MIN to MAX. Repeat this procedure for all

burners.

Pressure Testing

Remove left hand pan support and front left burner

cap and crown.
Fit manometer tube over the injector.
Turn on the burner gas supply and ignite another

burner supply.
The pressure reading should be nominally 20mbar

and must be between 17 mbar and 25mbar.
Turn off the burner supplies.

a) Minimum adjustment screw

b) Tap

FO 1032

F