21

Electrical connections

Any electrical work required to install this cooker

should be carried out by a qualified electrician or

competent person, in accordance with the current

regulations.

THIS COOKER MUST BE EARTHED.

The manufacturer declines any liability should these

safety measures not be observed.

This cooker is designed to be connected to a 230-

240V 50Hz AC electrical supply.

Before switching on, make sure the electricity supply

voltage is the same as that indicated on the cooker rating

plate. The rating plate is located on the oven frame.

The cooker is supplied with a 3 core flexible supply cord

incorporating a 13amp plug fitted. In the event of having

to change the fuse, a 13amp ASTA approved (BS 1362)

fuse must be used.

Should the plug need to be replaced for any reason, the

wires in the mains lead are coloured in accordance with

the following code:

Green and Yellow - Earth

Blue

- Neutral

Brown

- Live

— Connect the green and yellow (earth) wire to

the terminal in the plug which is marked with
the letter 'E' or the earth symbol

or coloured

green and yellow.

— Connect the blue (neutral) wire to the terminal

in the plug which is marked with the letter 'N'

or coloured black.

— Connect the brown (live) wire to the terminal in

the plug which is marked with the letter 'L' or

coloured red.

NOTE: The earth wire should be about 2 cm. longer
than the live and neutral wires.
Upon completion there must be no cut, or stray strands

of wire present and the cord clamp must be secure over

the outer sheath.

A cut off plug inserted into a 13 amp socket

is a serious safety (shock) hazard. Ensure

that the cut off plug is disposed of safely.

Permanent Connection

In the case of a permanent connection, it is necessary

that you install a double pole switch between the cooker

and the electricity supply (mains), with a minimum gap

of 3 mm. between the switch contacts and of a type

suitable for the required load in compliance with the

current electric regulations.

The switch must not break the yellow and green earth

cable at any point.

Ensure that the cooker supply cord does not

come into contact with surfaces with

temperatures higher than 50 deg. C.