Caution – Exmark Lazer ZHP User Manual
Page 27

- 22 -
c)
Remove vent caps from battery. Fill with water (distilled is recommended)
to bottom of vent wells and replace vent caps.
d)
See Assembly Section 3.2, for servicing a new battery.
PART NO. 513747
LOCATION: Top Center of Console
Under Front of Seat
5.1.4
Clean grass build-up under deck.
Service Interval: Daily
a)
Stop engine and remove key.
b)
Raise deck to the transport (4.5” cutting height) position.
Lift the front of unit and support unit using jack stands or equivalent support.
CAUTION
POTENTIAL HAZARD
♦
Raising the mower deck for service or maintenance
relying solely on mechanical or hydraulic jacks could
be dangerous.
WHAT CAN HAPPEN
♦
The mechanical or hydraulic jacks may not be enough
support or may misfunction allowing the unit to fall,
which could cause injury.
HOW TO AVOID THE HAZARD
♦
DO NOT rely solely on mechanical or hydraulic jacks
for support. Use adequate jack stands or equivalent
support.
c)
Clean out any grass build-up from underside of deck and in deck
discharge chute.
5.1.5
Check mower blades.
Service Interval: Daily
a)
Stop engine and remove key.
b)
Lift deck and secure in raised position as stated in Section 5.1.3 .
c)
Inspect blades and sharpen or replace as required.
d)
Torque blade bolts as shown. Be sure the spring disk washer cone is
installed toward the bolt head. (See Figure 4).