Maintenance and service – Enviro EG28-120 User Manual
Page 8
![background image](/manuals/86694/8/background.png)
Maintenance and Service
Periodically check to ensure that your direct vent system is clean.
Periodically check the pilot and burner. Check to see that all the burner ports are clean and clear. Check
the pilot head for blockage. Check to ensure the pilot flame is blue with no or very small yellow tips.
O
PENING
T
HE
D
OOR
:
���� ��
��� ������ �����
Figure 6: Removing the Door.
8
Turn unit off and wait until the appliance has cooled down.
1. Open the right hand hinged side flap, which will expose a door
fastener. Using a 1⁄2” wrench, loosen the fastener.
2. Due to the shape of the bay window door. You must also open
the left-hand side flap before attempting to open the door.
3. If the door must be removed open the door and lift the door
pins out of the hinges (see figure 6).
4. Ensure the door is properly fastened after cleaning before
attempting to re-light the appliance.
C
LEANING
T
HE
G
LASS
:
Allow the glass to cool before cleaning. It will be necessary to clean the ceramic glass periodically.
During a cold start up, condensation will sometimes form on the glass. This is a normal condition with
all gas fireplaces and stoves. However, this condensation can allow dust and lint to cling to the glass
surface. Initial paint curing of the appliance can leave behind a slight film on the glass. This is a temporary
problem. It is therefore recommended that the glass be cleaned initially after about the first four hour of
use. Depending upon the amount of use, cleaning should be required no more than two or three times
per season. To clean the door, use a mild glass cleaner and a soft cloth or a glass cleaner available from
your Enviro dealer. Abrasive cleaners will damage the glass.
T
O
R
EPLACE
D
OOR
:
The glass in this appliance is an integral part of the door assembly. If the glass is damaged or broken a
replacement inner door with glass assembly must be purchased.
The glass in this appliance is ceramic. If the glass is damaged or broken a factory door with glass
replacement must be used.
Remove the door with glass, a new door assembly must be purchased from an ENVIRO dealer (part #:
EG28-103). Do not use a substitute materials; it will void the warranty.
C
LEANING
T
HE
I
NSIDE
O
F
T
HE
F
IREBOX
:
1. Turn off the unit and allow it to cool down completely.
2. Remove the logs carefully from the firebox. Gently remove the embers and place on a piece of paper
towel, until ready to replace.
3. Vacuum the bottom of the firebox thoroughly. Carefully clean off any dust on the logs and remove any
lint from the main burner and pilot burner.
4. After carefully replacing the log and embers in their correct positions (see S
ECONDARY
I
NSTALLATION
-
I
NSTALLATION
OF
L
OG
S
ET
AND
E
MBERS
), and the door has been resealed, re-light the pilot, following the
instructions on the lighting label attached to the unit.