beautypg.com

Operating instructions – Enviro EG28-120 User Manual

Page 7

background image

Figure 4: Gas Valve.

Figure 3: Pilot Burning.

tips, are not getting enough air. Open the venturi until the flames clean up. If the venturi is opened, or

closed all the way, and the correct flames cannot be attained, turn off the gas and contact the dealer.

Figure 5: Venturi Adjustment.

Operating Instructions

7

A

DJUSTING

T

HE

V

ENTURIES

:

• Remove the ash shelf by undoing the screw at each end, pull shelf towards you.

• Remove one screw from the cover plate located below the ash shelf. Loosen the other screw (do not

remove) swing the cover plate out of the way and tighten screw down to hold it in place.

• With along screwdriver rotate spring clips to open or close the shutter to the desired setting.
The venturies allows the amount of air coming into the fireplace

to be adjusted in order to accommodate different climates and

venting arrangements. Start the pilot and then the burner. Make

sure the pilot flame is burning normally and none of the burner

ports are plugged. Let the fireplace burn for roughly fifteen

minutes and then examine the flames, compare the flames to

Figure 46.
The ideal flame will be blue at the base and light orange above.

The flames should be of medium height. If the flames look like

this, no venturi adjustment is needed. If the flames are fairly short

and mostly blue, the fireplace is getting too much air. Therefore,

the venturies should be closed slightly until the correct flames are

achieved. Flames that are very orange, with tall, dark, stringy

Table 1: Venturi Setting

NG

LP

Venturi Setting

1

/

16

” min. 1⁄4” min.

N

ORMAL

S

OUNDS

D

URING

O

PERATION

:

Table 2: Normal Sounds

Component

Sound & Reason

EG28

Creaking when heating up or cooling down.

Burner

Light pop or poof when turned off; this is more common with LP units.

Temperature Sensor

Clinking when it senses to turn the blower on or off.

Pilot Flame

Quiet whisper while the pilot flame in on.

Blower / Fan

Air movement that increase and decreases with the speed of the blower. The

blower is pushing the heat from the fireplace into the room.

Gas Control Valve

Dull click when turning on or off, this is the valve opening and closing.

Warning: Incorrect venturi adjustment may lead to improper

combustion, which is a safety hazard. Contact the dealer if