Ei Electronics Carbon Monoxide Alarm Ei 205ENA User Manual
Page 27
Testing with CO
: The red light flashes (as per Table B) within 10 seconds of
unit detecting CO.
Initialisation Time
: 70 seconds. On power up red and amber lights flash
momentarily to show they are operational.
Operating Temperature
: -10°C to 40°C
Humidity Range
: 15% to 95% R.H. (non-condensing)
Audible Alarm
: 85dB(A) at 3m minimum
Self Diagnostics
: Horn beep and amber fault light flashes every 40 seconds if a
sensor fault is found.
Tamperproof
: Locking Rivet(s) supplied.
Interconnect
: Up to 12, Ei205CEN Alarms can be interconnected, so
(Ei205CEN only)
that when one senses CO, all alarm.
CO Alarm Memory:
: A unit will indicate if it has been in alarm previously by
(Ei205EN
flashing the red light for 2 seconds every 40 seconds
& Ei205CEN only)
(2 flashes for 50 ppm CO, 4 flashes for 100 ppm CO and
8 flashes, for 300 ppm CO). When the test button is
pressed the red light flashes as per table B and also
indicates the previous CO alarm level detected. The
memory is cleared by holding down the test button until
the red light stops flashing.
27
B15583/R0/204EN&205EN/U&C 8/6/06 1:54 PM Page 27